Overview
Prophet XP Brochure
The Prophet Uplink 4610 is designed to interface with any instrumentation - new or existing, via industry standard 4-20 mA analog interface. The Prophet 4620 with integrated differential pressure sensor is a self-contained measurement and telemetry device. The 4600 series, combined with the TankLink portal, can be used to help prevent overfills, reduce run outs and eliminate emergency deliveries.
The UL Certified Prophet XP is designed for daily call outs to enable near real-time alarms, inventory (within 3% to 5%), and battery status are visible through the TankLink web service 24x7. Inventory and demand forecasting information is available anytime by simply logging on to the TankLink web site.
- No End User Facilities Required
Data is transmitted by the GSM or CDMA cellular network.
- No External Power Source is Required
Entire unit is powered by internal, replaceable, off-the-shelf lithium-ion batteries with an anticipated battery life of up to 2000 call outs.
- Simple Installation
A typical Prophet unit installation can take under 15 minutes, and can be easily installed by non-technical personnel. The unit can quickly and easily be redeployed if needed on any other tank.
- Sensor Flexibility
Interface to any existing instrumentation via 4-20 Current Loop Interface.
- Quick Commissioning
Once activated, final provisioning is done through a quick call to TankLink’s Customer Service and your inventory data is available on-line.
- Fixed Monitoring Costs
Subscription to the TankLink Monitoring Center includes internet access to data, plus all cellular long distance and roaming charges.
Key Functionality
- Remotely Programmable Call Out Times
- Set Initial Call Out Time
- Call Outs Per Day
- Day’s of Week
- End Devices Synchronize with Local Time from GSM Cellular Network
- Accurate Fill Capture and Notification
- WLAN Support for Up to Four (4) UpLinks
Specifications
|
Output Voltage
|
Nominally 24 VDC ± 5%
|
|
Output Current
|
Rated from 0-24 mA
|
|
Load Regulation
|
+/- 15% at 20 mA Load
|
|
Ripple
|
50 mV Peak-to-Peak
|
|
DC Isolation
|
100 MΩ with 200 VDC applied between output and case, input and case, and input and output
|
|
Output Short Circuit Protection
|
Output is current limited
|
|
Accuracy
|
± 1% of Span
|
|
Ambient Temp. Range
|
-20 to 160° F
(-28 to 71° C)
|
|
Battery
|
Replaceable lithium-ion
batteries (CR-123A)
|
|
Expected Battery Life
|
Up to 2000 call outs
|
|
Cellular Communication
|
GSM Digital Wireless
Quad Band
CDMA
|
|
Housing
|
NEMA 4X, weatherproof,
UL approved (UL94V0),
polypropylene construction
|
|
Area Classification
|
General purpose environment
|